IRIS POWER

PDA-IV – Partial Discharge Monitoring

Periodic Online Partial Discharge Monitoring for Hydrogenerators

Product Overview

The PDA-IV is the leading portable instrument to monitor partial discharge in hydrogenerators equipped with Iris Power Epoxy Mica Capacitor Couplers

Download Brochure
Works with the Following Assets
Assists with the Following Type of Monitoring

Iris Power uses the PDA-IV to periodically collect voltage pulse data through 80pF Iris Power Epoxy Mica Capacitors on Hydro Generators and analyzes the data using PDView diagnostic software to provide information need to avoid catastrophic failures, extending the life your asset and reducing the risk of unplanned outages.

All data analysis results automatically output from PDView provide information need to understand the severity and location of:

The results are the most repeatable and reliable information available which can also be referenced against the Iris Power severity tables which consist of a statistical review of over 700,000 machine tests globally to provide a relative health index against similar machines.

Product Details

Features

Acquisition

  • Connect with up to 12 permanently installed Iris Power 80pF Epoxy Mica Capacitors (EMC)
  • Operates on machines with either 50Hz or 60Hz power frequency

Data Analysis

  • Sophisticated monitoring and analysis system prevents false indications by digitally separating partial discharges from electrical noise, on a pulse-by-pulse basis.
  • Proven filtering algorithms enhances noise separation to allowing for a reliable and objective detection of stator winding problems such as  poor impregnation, overheated windings, coil movement in the slot, ineffective or deteriorating grading / semi-conductive material problems, and  contamination.
  • In response to a partial discharge alert, users can review the pulse height analysis plots, and the 32-window phase resolved partial discharge plots using basic interpretation to confirm the cause of the alert
  • PDView software performs automatic assessment and displays alerts to when high partial discharge conditions are detected.

Options

Data Acquisition

  • Low frequency option  for offline testing with one portable 16 kV coupler
  • Low frequency option for offline testing with one portable 25 kV coupler
  • Optional configuration to measure partial discharges on up to 12 EMC couplers for hydro generators (TGA-BP)
  • Optional configuration to measure partial discharges on up to 6 Iris Power Stator Slot Couplers (TGA-SP)

 

Get a Quote

Call us at +1 905.677.4824 or Toll Free at +1 888-873-4747 or fill out our online quote form below.

Learning Center

This Resource Library is designed to provide current, relevant resources that provide technical knowledge and practical solutions for owners and operators of rotating machines. We encourage you to use the search feature and filters to locate specific resources of interest.

RESOURCE LIBRARY

Articles, Technical Papers, & Case Studies

Stator End-Winding Vibration in Two-Pole Machines – Avoiding Generator Failure

IN THE PAST 15 YEARS, INSURANCE INDUSTRY DATA HAVE indicated that stator end-winding vibration has become the most important ...

BROWSE OUR RESOURCE LIBRARY

COURSES & TRAINING

Hands-on, practical experience

EL CID Training | Electromagnetic Core Imperfection Detection – October 1-3, 2024 – Iris Power, Toronto, Canada

Reasons to Take The Course Mechanical, electrical and environmental stresses can cause a breakdown in the inter-laminar insulation on Stator Core…

BROWSE OUR COURSES

IRMC 2024 June 17-20, 2024 - Renaissance Las Vegas, Las Vegas NV

IRMC 2024
LEARN MORE

Looking for more Information

Sign up to receive our latest whitepapers, webinars, new product information, product updates and more.